BORNEO BPI 00
						Minimum order =
													25 linear(s) metter(s)											
				
										Not in stock
									
			- Flame retardant

 - Acoustic

 - Thermal

 - Darkening

 
Uses
					- 
							Roman blinds
							 - 
							Curtains
							 
Composition
							100% FR polyester
						Weight
							440 g/m2
						Weight
								1232 g/ml
							Width
							
								280 cm							
						Fabric direction
														Room high or standard direction								
									
									
										
											
										
											
											
									
								
							
													Room high or standard direction
											CS/SN
												Room high or standard direction conception
											
Fitting
							
															L. : 20.0 cm - H. : 20.0 cm
														
						Maintenance advice
							- Washing mechanical action reduced to 30°
 - Do not bleach
 - Spin drying (at maximum 60 °C)
 - Iron at 160°C maximum
 - Do not dry clean
 - Professional water cleaning
 - Maintenance advice
 
Certifications
							
OEKO-TEX STANDARD 100 (CQ 1006/1)
Fire ranking
							
																											M1 /
																																				B1 /
																																				IMO PASS /
																																				UNI 8456 / 9174 Classe Uno
																								
						Acoustic
							
								Noise reduction coefficient (NRC) :0.89
								Weighted sound absorption coefficient (αw) :0.90
								Acoustic absorption class :A
							
						Optical index
							
																	Light reflexion60 %
Light absorption40 %
Light transmission0 %
						Light absorption40 %
Light transmission0 %
Thermal index
							
																	Solar reflexion56 %
Solar absorption44 %
Solar transmission0 %
UV transmission0 %
GtotGt 39 % Fc 65 %
										
										
											
												
											
												
										
									
																		
						Solar absorption44 %
Solar transmission0 %
UV transmission0 %
GtotGt 39 % Fc 65 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
													Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
Resilience
							
																	Lightfastness (units Class/8)6
																																									
						- Dimentional Stability (%)											
- Warp-0.5
 - Weft0
 
 
- Breaking Elongation											
- Warp31
 
 
- Breaking load (daN)											
- Warp130
 - Weft250
 
 