Skip to main content Skip to navigation
Range
  • BIOSAT METIS 2162
  • BIOSAT METIS 2162
  • BIOSAT METIS 2162

BIOSAT METIS 2162 Lin 11

Pattern : False plain
Minimum order = 25 linear(s) metter(s)
Not in stock
  • Flame retardant
  • Antiviral
  • Antibacterial
  • Acoustic
  • Thermal
    Thermal

Combine aesthetics and well-being with high-tech fibres for antibacterial and antiviral action : kills 99% of bacteria (tested on staphylococcus aureus et klebsiella pneumoniae). BIOSAT was tested on 2 virus strains: the enveloped human coronavirus HCoV-229 (similar to Covid-19) and the non-enveloped Murine Norovirus (similar to the gastroenteritis virus). For the former, BIOSAT kills nearly 98% of the virus in less than 2 hours and for the latter, 73% in less than 2 hours.

Uses
  • Roman blinds
    Roman blinds
  • Panel curtains
    Panel curtains
  • Curtains
    Curtains
  • Partition curtain
    Partition curtain
Composition
polyester/polyester FR bioactive
Weight
135 g/m2
Width
280 cm
Fabric direction
Room high or standard direction
?

Room high or standard direction

CS/SN

Room high or standard direction conception

Maintenance advice
  • Washing mechanical action reduced to 60°
  • Do not bleach
  • Do not spin dry
  • Iron at 110°C maximum
  • Dry cleaning allowed
Labels
France Terre Textile (R016)
Certifications
OEKO-TEX STANDARD 100 (CQ 1006/1)
Fire ranking
M1 / B1 / IMO PASS / UNI 8456 / 9174 Classe Uno
Acoustic
Noise reduction coefficient (NRC) :0.72 Weighted sound absorption coefficient (αw) : Acoustic absorption class :Unclassified
Antibacterial
Yes
Optical index
Light reflexion57 %
Light absorption16 %
Light transmission27 %
Thermal index
Solar reflexion53 %
Solar absorption19 %
Solar transmission28 %
UV transmission2 %
GtotGt 40 % Fc 68 %
?

gt/Fc

Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1

gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.

Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.

Resilience
Lightfastness (units Class/8)6
Pilling5
Martindale (Cycles)14000
  • Dimentional Stability (%)
    • Warp-0.5
    • Weft-0.5
  • Breaking Elongation
    • Warp43
    • Weft37
  • Breaking load (daN)
    • Warp42
    • Weft129
Roman blinds
Roman blinds
Panel curtains
Panel curtains
Curtains
Curtains
Partition curtain
Partition curtain