6046 Naturel 26
Printing design "nature" theme. Tone-on-tone plant pattern, perfect for a charming décor.
For the choice of the printing support and its width (width), please contact us.
- Flame retardant
- Acoustic
- Thermal
- Darkening
Standard Direction

SD
Standard direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp17
- Weft27
- Breaking load (daN)
- Warp87
- Weft110




- Flame retardant
- Acoustic
- Thermal
- Darkening
Room High Direction

RD
Room High Direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp17
- Weft27
- Breaking load (daN)
- Warp87
- Weft110




- Flame retardant
- Antiviral
- Antibacterial
- Acoustic
- Thermal
Room High Direction

RD
Room High Direction conception
- Wash at 60° maximum
- Bleach using oxygenated agents only
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Pilling5
Martindale (Cycles)14000
- Dimentional Stability (%)
- Warp-0.5
- Weft-0.5
- Breaking Elongation
- Warp43
- Weft37
- Breaking load (daN)
- Warp42
- Weft129




- Flame retardant
- Acoustic
- Thermal
- Darkening
Standard Direction

SD
Standard direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp17
- Weft27
- Breaking load (daN)
- Warp87
- Weft110





- Flame retardant
- Acoustic
- Thermal
- Darkening
Room High Direction

RD
Room High Direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp17
- Weft27
- Breaking load (daN)
- Warp87
- Weft110





- Flame retardant
- Sheer
Room High Direction

RD
Room High Direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp46
- Weft13
- Breaking load (daN)
- Warp41
- Weft40



Standard Direction

SD
Standard direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption94 %
Light transmission1 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Pilling5
Martindale (Cycles)40000
- Dimentional Stability (%)
- Warp-2
- Weft-1
- Breaking Elongation
- Warp38
- Weft21
- Breaking load (daN)
- Warp150
- Weft93







Room High Direction

RD
Room High Direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption94 %
Light transmission1 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Pilling5
Martindale (Cycles)40000
- Dimentional Stability (%)
- Warp-2
- Weft-1
- Breaking Elongation
- Warp38
- Weft21
- Breaking load (daN)
- Warp150
- Weft93







- Flame retardant
- Occulting
Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption29 %
Light transmission0 %
Solar absorption34 %
Solar transmission0 %
UV transmission0 %
GtotGt 35 % Fc 60 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
- Dimentional Stability (%)
- Warp-0,5
- Weft0
- Breaking Elongation
- Warp19
- Weft22
- Breaking load (daN)
- Warp37
- Weft57





Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption18 %
Light transmission0 %
Solar absorption26 %
Solar transmission0 %
UV transmission0 %
GtotGt 33 % Fc 55 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
- Dimentional Stability (%)
- Warp-0,5
- Weft0
- Breaking Elongation
- Warp26
- Weft15
- Breaking load (daN)
- Warp62
- Weft31




- Flame retardant
Room High Direction

RD
Room High Direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption0 %
Light transmission0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Martindale (Cycles)0
- Breaking Elongation
- Breaking load (daN)
- Warp0
- Weft0



- Flame retardant
Standard Direction

SD
Standard direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption0 %
Light transmission0 %
Solar absorption0 %
Solar transmission0 %
UV transmission0 %
GtotGt 0 % Fc 0 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Martindale (Cycles)0
- Breaking Elongation
- Breaking load (daN)
- Warp0
- Weft0



Room High Direction

RD
Room High Direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp-1
- Weft-1
- Breaking Elongation
- Warp42
- Weft22
- Breaking load (daN)
- Warp160
- Weft140



Standard Direction

SD
Standard direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp-1
- Weft-1
- Breaking Elongation
- Warp42
- Weft22
- Breaking load (daN)
- Warp160
- Weft140



Room High Direction

RD
Room High Direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption4 %
Light transmission71 %
Solar absorption3 %
Solar transmission72 %
UV transmission65 %
GtotGt 50 % Fc 85 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
- Dimentional Stability (%)
- Warp-1
- Weft0
- Breaking Elongation
- Warp28
- Weft34
- Breaking load (daN)
- Warp30
- Weft36



- Flame retardant
- Antibacterial
- Thermal
Room High Direction

RD
Room High Direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry




Standard Direction

SD
Standard direction conception
- Wash at 30°C maximum
- Dry clean only
- Do not bleach
- Iron at 110°C maximum
- Do not spin dry
- Dimentional Stability (%)
- Warp-1
- Weft0
- Breaking Elongation
- Warp69
- Weft106
- Breaking load (daN)
- Warp52
- Weft41



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp38
- Weft38
- Breaking load (daN)
- Warp170
- Weft120



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp38
- Weft38
- Breaking load (daN)
- Warp170
- Weft120



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp-1
- Weft0
- Breaking Elongation
- Warp69
- Weft106
- Breaking load (daN)
- Warp52
- Weft41



- Flame retardant
- Acoustic
- Thermal
- Recycled fabrics
Room high or standard direction

CS/SN
Room high or standard direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption40 %
Light transmission8 %
Solar absorption24 %
Solar transmission15 %
UV transmission3 %
GtotGt 37 % Fc 63 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Pilling4-5
Martindale (Cycles)90000
- Dimentional Stability (%)
- Warp-1,5
- Weft-1,5
- Breaking Elongation
- Warp41
- Weft44
- Breaking load (daN)
- Warp180
- Weft150








- Flame retardant
- Acoustic
- Thermal
- Recycled fabrics
Room high or standard direction

CS/SN
Room high or standard direction conception
- Wash at 40° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption51 %
Light transmission8 %
Solar absorption29 %
Solar transmission16 %
UV transmission5 %
GtotGt 39 % Fc 66 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
Pilling4-5
Martindale (Cycles)90000
- Dimentional Stability (%)
- Warp-1,5
- Weft-1,5
- Breaking Elongation
- Warp41
- Weft44
- Breaking load (daN)
- Warp180
- Weft150








Standard Direction

SD
Standard direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Pilling5
Martindale (Cycles)60000



- Occulting
- Thermal
Room high or standard direction

CS/SN
Room high or standard direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Light absorption18 %
Light transmission0 %
Solar absorption26 %
Solar transmission0 %
UV transmission0 %
GtotGt 33 % Fc 55 %
gt/Fc
Echantillon testé selon la norme DIN EN 410 2011 fixant les méthodes de mesures et de calcul en référence à la norme EN 13 363-1
gt = 0.73 = Facteur solaire du vitrage par référence.
Double vitrage isolant faiblement émissif dont le facteur de transmission thermique du vitrage seul est U=1.6W/m2k.
Fc=facteur obscurissement FC des matéraiux de protection solaire selon la norme DIN EN14501.
- Dimentional Stability (%)
- Warp-0,5
- Weft0
- Breaking Elongation
- Warp26
- Weft15
- Breaking load (daN)
- Warp62
- Weft31



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry



Room High Direction

RD
Room High Direction conception
- Wash at 60° maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
Pilling3
Martindale (Cycles)25000
- Dimentional Stability (%)
- Warp-3
- Weft-1
- Breaking Elongation
- Warp36
- Weft36
- Breaking load (daN)
- Warp170
- Weft60



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp-0,5
- Weft-0,5
- Breaking Elongation
- Warp28
- Weft12
- Breaking load (daN)
- Warp140
- Weft57



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp0
- Weft0
- Breaking Elongation
- Warp40
- Weft32
- Breaking load (daN)
- Warp190
- Weft93



Room High Direction

RD
Room High Direction conception
- Wash at 30°C maximum
- Do not bleach
- Iron at 110°C maximum
- Dry cleaning allowed
- Do not spin dry
- Dimentional Stability (%)
- Warp-1
- Weft0
- Breaking Elongation
- Warp31
- Weft8
- Breaking load (daN)
- Warp120
- Weft43