6041 Taupe 95
Printing design geometric theme. Tone-on-tone plant pattern, perfect for a charming décor.
For the choice of the printing support and its width (width), please contact us.
- Flame retardant

 - Acoustic

 - Thermal

 - Darkening

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp17
 - Weft27
 
 
- Breaking load (daN)													
- Warp87
 - Weft110
 
 



- Flame retardant

 - Antiviral

 - Antibacterial

 - Acoustic

 - Thermal

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Bleach using oxygenated agents only
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Martindale (Cycles)14000
- Dimentional Stability (%)													
- Warp-0.5
 - Weft-0.5
 
 
- Breaking Elongation													
- Warp43
 - Weft37
 
 
- Breaking load (daN)													
- Warp42
 - Weft129
 
 




- Flame retardant

 - Acoustic

 - Thermal

 - Darkening

 
Standard Direction
													SD
														Standard direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp17
 - Weft27
 
 
- Breaking load (daN)													
- Warp87
 - Weft110
 
 


- Flame retardant

 - Acoustic

 - Thermal

 - Darkening

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp17
 - Weft27
 
 
- Breaking load (daN)													
- Warp87
 - Weft110
 
 


- Flame retardant

 - Sheer

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 40°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp46
 - Weft13
 
 
- Breaking load (daN)													
- Warp41
 - Weft40
 
 



Standard Direction
													SD
														Standard direction conception
													
- Washing mechanical action reduced to 60°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption94 %
Light transmission1 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
Pilling5
Martindale (Cycles)40000
- Dimentional Stability (%)													
- Warp-2
 - Weft-1
 
 
- Breaking Elongation													
- Warp38
 - Weft21
 
 
- Breaking load (daN)													
- Warp150
 - Weft93
 
 







Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption94 %
Light transmission1 %
Solar absorption48 %
Solar transmission13 %
UV transmission0 %
GtotGt 48 % Fc 69 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
Pilling5
Martindale (Cycles)40000
- Dimentional Stability (%)													
- Warp-2
 - Weft-1
 
 
- Breaking Elongation													
- Warp38
 - Weft21
 
 
- Breaking load (daN)													
- Warp150
 - Weft93
 
 







- Flame retardant

 - Occulting

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption29 %
Light transmission0 %
Solar absorption34 %
Solar transmission0 %
UV transmission0 %
GtotGt 35 % Fc 60 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-0,5
 - Weft0
 
 
- Breaking Elongation													
- Warp19
 - Weft22
 
 
- Breaking load (daN)													
- Warp37
 - Weft57
 
 





Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption18 %
Light transmission0 %
Solar absorption26 %
Solar transmission0 %
UV transmission0 %
GtotGt 33 % Fc 55 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-0,5
 - Weft0
 
 
- Breaking Elongation													
- Warp26
 - Weft15
 
 
- Breaking load (daN)													
- Warp62
 - Weft31
 
 




Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-1
 - Weft-1
 
 
- Breaking Elongation													
- Warp42
 - Weft22
 
 
- Breaking load (daN)													
- Warp160
 - Weft140
 
 



Standard Direction
													SD
														Standard direction conception
													
- Washing mechanical action reduced to 60°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-1
 - Weft-1
 
 
- Breaking Elongation													
- Warp42
 - Weft22
 
 
- Breaking load (daN)													
- Warp160
 - Weft140
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 40°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption4 %
Light transmission71 %
Solar absorption3 %
Solar transmission72 %
UV transmission65 %
GtotGt 50 % Fc 85 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-1
 - Weft0
 
 
- Breaking Elongation													
- Warp28
 - Weft34
 
 
- Breaking load (daN)													
- Warp30
 - Weft36
 
 



- Flame retardant

 - Antibacterial

 - Thermal

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 




Standard Direction
													SD
														Standard direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Washing prohibited
 - Do not bleach
 - Do not spin dry
 - Do not iron
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-1
 - Weft0
 
 
- Breaking Elongation													
- Warp69
 - Weft106
 
 
- Breaking load (daN)													
- Warp52
 - Weft41
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp38
 - Weft38
 
 
- Breaking load (daN)													
- Warp170
 - Weft120
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp38
 - Weft38
 
 
- Breaking load (daN)													
- Warp170
 - Weft120
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-1
 - Weft0
 
 
- Breaking Elongation													
- Warp69
 - Weft106
 
 
- Breaking load (daN)													
- Warp52
 - Weft41
 
 



- Flame retardant

 - Acoustic

 - Thermal

 - Recycled fabrics

 
Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Washing mechanical action reduced to 40°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption40 %
Light transmission8 %
Solar absorption24 %
Solar transmission15 %
UV transmission3 %
GtotGt 37 % Fc 63 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
Pilling4-5
Martindale (Cycles)90000
- Dimentional Stability (%)													
- Warp-1,5
 - Weft-1,5
 
 
- Breaking Elongation													
- Warp41
 - Weft44
 
 
- Breaking load (daN)													
- Warp180
 - Weft150
 
 








- Flame retardant

 - Acoustic

 - Thermal

 - Recycled fabrics

 
Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Washing mechanical action reduced to 40°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption51 %
Light transmission8 %
Solar absorption29 %
Solar transmission16 %
UV transmission5 %
GtotGt 39 % Fc 66 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
Pilling4-5
Martindale (Cycles)90000
- Dimentional Stability (%)													
- Warp-1,5
 - Weft-1,5
 
 
- Breaking Elongation													
- Warp41
 - Weft44
 
 
- Breaking load (daN)													
- Warp180
 - Weft150
 
 








Standard Direction
													SD
														Standard direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Pilling5
Martindale (Cycles)60000



- Occulting

 - Thermal

 
Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption18 %
Light transmission0 %
Solar absorption26 %
Solar transmission0 %
UV transmission0 %
GtotGt 33 % Fc 55 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-0,5
 - Weft0
 
 
- Breaking Elongation													
- Warp26
 - Weft15
 
 
- Breaking load (daN)													
- Warp62
 - Weft31
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 60°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Pilling3
Martindale (Cycles)25000
- Dimentional Stability (%)													
- Warp-3
 - Weft-1
 
 
- Breaking Elongation													
- Warp36
 - Weft36
 
 
- Breaking load (daN)													
- Warp170
 - Weft60
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-0,5
 - Weft-0,5
 
 
- Breaking Elongation													
- Warp28
 - Weft12
 
 
- Breaking load (daN)													
- Warp140
 - Weft57
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp40
 - Weft32
 
 
- Breaking load (daN)													
- Warp190
 - Weft93
 
 



Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp-1
 - Weft0
 
 
- Breaking Elongation													
- Warp31
 - Weft8
 
 
- Breaking load (daN)													
- Warp120
 - Weft43
 
 



- Flame retardant

 - Sheer

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 40°, moderate program
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
- Dimentional Stability (%)													
- Warp0.5
 - Weft0
 
 
- Breaking Elongation													
- Warp36
 - Weft33
 
 
- Breaking load (daN)													
- Warp31
 - Weft23
 
 



- Flame retardant

 - Acoustic

 - Thermal

 - Darkening

 
Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Spin drying (at maximum 60 °C)
 - Iron at 160°C maximum
 - Do not dry clean
 - Professional water cleaning
 
Light absorption40 %
Light transmission0 %
Solar absorption44 %
Solar transmission0 %
UV transmission0 %
GtotGt 39 % Fc 65 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-0.5
 - Weft0
 
 
- Breaking Elongation													
- Warp31
 
 
- Breaking load (daN)													
- Warp130
 - Weft250
 
 


- Flame retardant

 - Sheer

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Do not spin dry
 - Iron at 160°C maximum
 - Dry cleaning allowed
 
Light absorption2 %
Light transmission65 %
Solar absorption4 %
Solar transmission64 %
UV transmission50 %
GtotGt 48 % Fc 81 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp0
 - Weft0
 
 
- Breaking Elongation													
- Warp69
 - Weft58
 
 
- Breaking load (daN)													
- Warp47
 - Weft24
 
 



Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Hand washing
 - Do not bleach
 - Do not spin dry
 - Do not iron
 - Dry cleaning allowed
 
Martindale (Cycles)50000


- Occulting

 - Thermal

 
Room High Direction
													RD
														Room High Direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Spin drying (at maximum 60 °C)
 - Iron at 160°C maximum
 - Do not dry clean
 - Professional water cleaning
 
Light absorption47 %
Light transmission0 %
Solar absorption36 %
Solar transmission0 %
UV transmission0 %
GtotGt 36 % Fc 61 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-1
 - Weft-1
 
 
- Breaking Elongation													
- Warp48
 - Weft72
 
 
- Breaking load (daN)													
- Warp51
 - Weft84
 
 



- Flame retardant

 - Thermal

 
Room high or standard direction
													CS/SN
														Room high or standard direction conception
													
- Washing mechanical action reduced to 30°
 - Do not bleach
 - Do not spin dry
 - Iron at 110°C maximum
 - Dry cleaning allowed
 
Light absorption5 %
Light transmission32 %
Solar absorption5 %
Solar transmission32 %
UV transmission25 %
GtotGt 37 % Fc 62 %
gt/Fc
Sample tested according to norm DIN EN 410 2011 defining the measurements and calculation methods in accordance to norm EN 13 363-1.
gt = 0.59 = referenced solar factor of glazing
															Double Glazing with argon filling and low-e coating of which the thermal energetic transmission is U= 1.2 W/m2k.
Fc=shade masking factor of solar protection material as per norm DIN EN14501.
- Dimentional Stability (%)													
- Warp-0.5
 - Weft-0.5
 
 
- Breaking Elongation													
- Warp25
 - Weft10
 
 
- Breaking load (daN)													
- Warp45
 - Weft23
 
 